Compact Flow Meter with Temperature Input for Corrosive Process Monitoring

Compact Flow Meter with Temperature Input for Corrosive Process Monitoring

Some compact process points need both flow and an indication of temperature, in corrosive surroundings and tight pipe runs. The YF-E5 combines clamp-on flow measurement with an optional temperature input and a PTFE-coated, corrosion-resistant housing.

The challenge

  • Space is limited around small process pipes.
  • The area is corrosive, requiring protected construction.
  • Operators want flow and temperature from one point.
  • Installation must avoid shutdown and cutting.

The solution: YF-E5

The YF-E5 is a compact magnetic clamp-on meter with an optional temperature-sensor input and PTFE anti-corrosion housing. See the YF-E5 specifications →

  • Pipe OD 9-277 mm (DN6-DN100+).
  • Integrated or split/remote configuration.
  • Optional temperature input (energy-ready).
  • Medium-temperature versions up to 120 °C.
  • Magnetic tool-free mounting and PTFE-coated housing.

Configuration used in this application

Meter YF-E5 compact transit-time
Pipe OD range 9-277 mm (DN6-DN100+)
Configuration Integrated clamp-on or split (remote)
Optional input Temperature sensor (energy-ready)
Medium temperature 0-50 / 0-70 / 0-120 °C versions
Housing Aluminium alloy / PTFE anti-corrosion
Outputs 4-20 mA, RS485 (Modbus RTU), OCT

How it is deployed

  1. Choose the temperature version matching the process.
  2. Clamp the sensor magnetically at a straight small-pipe section.
  3. Fit the optional temperature input and wire power and outputs.
  4. Confirm flow reading and temperature indication with the operator.

What the operator gets

  • Flow and temperature observed at one compact point.
  • Corrosion-resistant installation in aggressive areas.
  • No process shutdown or pipe cutting.
  • A path to simple energy monitoring later.

Frequently asked questions

Can the YF-E5 also measure temperature?

It accepts an optional temperature-sensor input, making it energy-ready alongside clamp-on flow measurement.

What temperature versions are available?

Versions cover 0-50 C, 0-70 C and 0-120 C medium temperature.

Is the housing suitable for corrosive areas?

Yes, the aluminium-alloy housing has PTFE anti-corrosion protection.

Have a similar requirement?

Send us your pipe size, pipe material, fluid, temperature and quantity. Our engineers will recommend the right configuration and reply with factory-direct wholesale/OEM pricing in English.

Request a Quote →💬 WhatsApp an Engineer


Browse our complete range on the Products page.

Questions about your application? Contact our team or request a quote — we respond within 24 hours.