Clamp-On Energy Meter for HVAC Chilled Water Allocation and Tenant Billing

Clamp-On Energy Meter for HVAC Chilled Water Allocation and Tenant Billing

In multi-tenant buildings and district cooling, each consumer should pay for the cooling energy they actually use. The YF-E6 clamp-on energy meter calculates thermal energy from flow and supply/return temperature, installed on existing pipes without shutdown.

The challenge

  • Tenants need fair, usage-based cooling allocation.
  • Existing chilled-water pipes cannot be cut for an inline heat meter.
  • Energy calculation needs accurate flow and paired temperature.
  • Billing systems require reliable serial data.

The solution: YF-E6

The YF-E6 is a clamp-on ultrasonic energy meter combining flow measurement with matched supply/return temperature sensors. See the YF-E6 specifications →

  • Flow accuracy ±1.0%, energy accuracy ±2.0%.
  • Temperature-pairing accuracy ±0.2 °C.
  • DN25-DN2000 pipe range.
  • RS485 Modbus RTU and 4-20 mA output.
  • 24 VDC with backup for metering continuity.

Configuration used in this application

Meter YF-E6 clamp-on ultrasonic energy meter
Flow accuracy ±1.0% (0.5-5.0 m/s)
Energy accuracy ±2.0%
Temperature pairing ±0.2 °C
Pipe size DN25-DN2000 (1″-80″)
Power supply 24 VDC @ 5 W (CR1220 backup)
Communication RS485, Modbus RTU
Analog output 4-20 mA (load ≤750 Ω)

How it is deployed

  1. Install flow transducers on the chilled-water line to the tenant or zone.
  2. Mount and pair supply/return temperature sensors.
  3. Wire 24 VDC and connect Modbus to the energy/billing system.
  4. Verify pairing and totalize energy for the billing period.

What the operator gets

  • Fair, measured cooling-energy allocation.
  • Installation on live systems without shutdown.
  • Accurate paired temperature for credible energy data.
  • Reliable data feed for billing and reconciliation.

Frequently asked questions

How does the YF-E6 calculate cooling energy?

It combines clamp-on flow measurement with matched supply and return temperature sensors to calculate thermal energy over time.

Can it be installed on operating chilled-water pipes?

Yes, the flow sensors clamp externally, so the system keeps running with no pipe cutting.

How accurate are the flow and temperature measurements?

Flow accuracy is +/-1.0%, energy accuracy +/-2.0% and paired temperature accuracy is +/-0.2 C.

Have a similar requirement?

Send us your pipe size, pipe material, fluid, temperature and quantity. Our engineers will recommend the right configuration and reply with factory-direct wholesale/OEM pricing in English.

Request a Quote →💬 WhatsApp an Engineer


Browse our complete range on the Products page.

Questions about your application? Contact our team or request a quote — we respond within 24 hours.