Magnetic Clamp-On Flow Meter for a Chemical Dosing Skid Retrofit

Magnetic Clamp-On Flow Meter for a Chemical Dosing Skid Retrofit

Chemical dosing skids often need a flow monitor added after build, where shutting down or cutting small corrosion-resistant lines is undesirable. The YF-C3M adds measurement with a tool-free magnetic snap-on mount and standard control outputs.

The challenge

  • Adding a meter after manufacture should not require pipe modification.
  • Small chemical lines run from DN6 to DN100.
  • Control systems need 4-20 mA and Modbus signals.
  • The environment demands corrosion-resistant construction.

The solution: YF-C3M

The YF-C3M is a compact transit-time meter with a magnetic snap-on bracket for tool-free installation on small chemical lines. See the YF-C3M specifications →

  • Pipe OD 9-115 mm (DN6-DN100).
  • Integrated clamp-on or split/remote configuration.
  • Magnetic tool-free mounting bracket.
  • 4-20 mA, RS485 Modbus RTU and OCT outputs.
  • Anti-corrosion aluminium-alloy housing.

Configuration used in this application

Meter YF-C3M compact transit-time
Pipe OD range 9-115 mm (DN6-DN100)
Configuration Integrated clamp-on or split (remote)
Installation Magnetic snap-on bracket, tool-free
Outputs 4-20 mA, RS485 (Modbus RTU), OCT
Housing Aluminium alloy / anti-corrosion
Typical liquids Water, solutions, chemicals (clean, full pipe)

How it is deployed

  1. Confirm fluid compatibility and that the line is clean and full.
  2. Snap the magnetic bracket onto a straight section of small pipe.
  3. Wire 24 V power and 4-20 mA/Modbus to the skid controller.
  4. Commission dosing setpoints and verify the reading under operation.

What the operator gets

  • Flow monitoring added without shutdown or cutting.
  • Fast, tool-free retrofit on the skid.
  • Direct integration with dosing control.
  • Corrosion-resistant build for chemical areas.

Frequently asked questions

Does the fluid need to be clean for transit-time measurement?

Transit-time meters work best on clean, full-pipe liquids such as water, solutions and chemicals; heavily aerated or solids-laden fluids should be reviewed with our engineers.

How is the sensor mounted?

The YF-C3M uses a magnetic snap-on bracket, so installation is tool-free on suitable steel pipework.

What signals does it provide to the PLC?

It provides 4-20 mA, RS485 Modbus RTU and OCT outputs.

Have a similar requirement?

Send us your pipe size, pipe material, fluid, temperature and quantity. Our engineers will recommend the right configuration and reply with factory-direct wholesale/OEM pricing in English.

Request a Quote →💬 WhatsApp an Engineer


Browse our complete range on the Products page.

Questions about your application? Contact our team or request a quote — we respond within 24 hours.