News
-
Clamp-On Flow Meter for a Medium DN125-DN250 Process Water Line

Medium process water lines around DN125 to DN250 frequently need continuous metering for balance and control, but inline replacement means downtime. The purpose-sized YF-C3 configuration clamps directly onto these lines and feeds standard signals to the control system. The challenge The line is already installed and should stay in service. The DN125-DN250 range suits a…
-
Compact Flow Meter with Temperature Input for Corrosive Process Monitoring

Some compact process points need both flow and an indication of temperature, in corrosive surroundings and tight pipe runs. The YF-E5 combines clamp-on flow measurement with an optional temperature input and a PTFE-coated, corrosion-resistant housing. The challenge Space is limited around small process pipes. The area is corrosive, requiring protected construction. Operators want flow and…
-
Magnetic Clamp-On Flow Meter for a Chemical Dosing Skid Retrofit

Chemical dosing skids often need a flow monitor added after build, where shutting down or cutting small corrosion-resistant lines is undesirable. The YF-C3M adds measurement with a tool-free magnetic snap-on mount and standard control outputs. The challenge Adding a meter after manufacture should not require pipe modification. Small chemical lines run from DN6 to DN100.…
-
Small-Pipe Flow Meter for OEM Machinery and Test Equipment Integration

Builders of compact machines, test rigs and skids need to meter small-bore liquid lines where there is no room to cut in a traditional meter. The YF-C3 clamp-on meter covers outer diameters from 9 mm and integrates into equipment with minimal modification. The challenge Pipes are very small (from around 9 mm OD). Cutting into…
-
Portable Flow Meter for Large-Pipe Handover Acceptance and Flow Verification

When a new or modified large-bore industrial pipeline is handed over, owners and contractors need an independent flow check to prove the line and pumps meet specification. The YF-P2 portable clamp-on meter provides high-accuracy verification on very large pipes without any intrusive work. The challenge Acceptance tests demand higher accuracy than routine monitoring. Large diameters…
-
Portable Flow Meter for Municipal Water Pump Testing and DMA Night-Flow Surveys

Water utilities need to verify pump performance and detect leakage across district metered areas (DMAs) without taking mains out of service. The YF-P1 portable clamp-on ultrasonic flow meter lets one engineer move between sites, install on a live pressurised pipe in minutes and log flow for night-flow analysis. The challenge Pump stations and distribution mains…
-
Clamp-On Flow Meters in Pulp & Paper: Process and Cooling Water

Pulp and paper mills move large volumes of process, cooling and white water through steel, cast iron and lined pipes, and need flow data for process control, water balance and efficiency. On lines that are difficult or costly to shut down, a clamp-on meter installs externally with no cutting and no pressure loss. On cleaner…
-
Clamp-On Ultrasonic Flow Meters for Power Plant Circulating Cooling Water

Power plants use large quantities of water in circulating cooling, condenser and auxiliary systems. Reliable flow data supports cooling assurance, pump and condenser performance, efficiency and heat-rate monitoring — on large, critical pipes that must stay in service. Clamp-on ultrasonic meters install externally with no shutdown and no pressure loss, and cover the very large…
-
Clamp-On Flow Meters for Data Center Cooling Water Monitoring

Data centers depend on continuous cooling water to remove heat from servers. Flow measurement supports cooling assurance, pump monitoring, energy efficiency and capacity planning — on piping that cannot be shut down. A clamp-on meter installs externally on operating cooling lines, giving flow data without any risk to cooling continuity. Where they are used Chilled…
-
Non-Intrusive Flow Measurement in Food & Beverage: Process Water and CIP

Food and beverage plants measure water, ingredients, CIP (clean-in-place) return and utility lines under strict hygiene and uptime requirements. A clamp-on ultrasonic meter has a specific advantage here: nothing touches the fluid. The transducers sit on the outside of the pipe, so there are no wetted parts to contaminate product, no breach of a hygienic…